Description
Technical specifications
- Flush Fitting
- Self-resetting
- Contacts: Double pole NONC
- Output: 4 AMP contact @ 30V ACDC
- Wear resistant legend
- Vandal resistant
- Silver contacts
- Operating temperature -20° to +60°c
- Operating travel: 2mm
- Contact resistance: 10m OHM (Max)
- Operating life (mechanical): 1,000,000
Features:
Green dome button:
• Designed for normal operation, either momentary or using a standard time delay through your
control unit.
Stainless steel button:
• The emergency exit button will open the door for a minimum of 3 minutes, or more if required (when pressed)
RL03 timer module:
• 12V & 24V DC
• Contact rating 10A @ 125VAC or 10A @ 30VDC
• NC/COM/NO
• Positive or negative trigger
• 1 to 999 minutes